∙Do not panic when a firmware update fails! It is certainly not the camera that is defective, but one of its functions will not properly work. In such a case, just send the camera to KAMERA WERK DRESDEN GmbH to take care of the trouble.
∙Create a 'safe environment': Make sure the connections made on the camera and PC/IPC are mechanically safe, and see to it that the camera and PC/IPC are properly powered.
∙For a firmware update, always use the safest and fastest communication method between the camera and PC/IPC, if possible. Though one of the serial ports of the CameraLink™ interface may be used for an MCU firmware update, the
∙And last but not least an old thumb rule: ‚Do not change a running system!‘, i.e. do not update the firmware unless it is absolutely necessary.
Components of a firmware update for a LOGLUX® i5 CL camera:
∙an MCU firmware update file (*.txt)
∙an FPGA firmware update file (*.bin), and
∙the LOGLUX® LuxWare PC software
Some functions of the
An exception is the firmware update for the FPGA which may have
The following firmware update procedure is recommended:
The firmware update filesPrior to updating the firmware, the user must first unpack the firmware files provided by KAMERA WERK DRESDEN GmbH in form of a zip or other file, and load them into a folder of his choice.
Establishment of a serial connection∙Plug a null modem cable into the
Note: It is strongly recommended to use the
∙Putt he camera into operation and start the LOGLUX® LuxWare PC software.
∙In the start menu, select the desired camera in window ‘Camera
Selection‘ (image processing hardware scan, see chapter ‘Description of the LOGLUX® LuxWare configuration software/The start menu‘), then click ‚Connect‘.
Note: For the purpose of a faster data transmission during an update, the baud rate of the serial