Version 1.08 (04/07) | Manual: CMOS Industrial Camera LOGLUX® i5 |
⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯
The 'Look-up Table x' menu
This menu is used for loading one of the three
The user can enter the desired LUT name in the 'Name' field. All
The buttons under 'Actions' allow the user to choose from the following LUT functions:
∙ Read → The selected LUT is transferred from the camera to the host system (PC/IPC), and the function values are displayed under 'Lookup table contents'. By clicking button 'Save', the transferred LUT can be saved as a text file in the host system (PC/IPC).
∙ Load → A LUT (text file) in the host system is selected to be transferred to the camera. When the button is pressed, the standard
Windows® dialog 'Load LUT from ...' is opened, and the user can choose the desired file (in the
.TXT format). Clicking the 'Write' button transfers the selected LUT to the camera.
∙ Save / Write → A LUT transferred from the camera is saved as a text file in the host system LUT ('Save'), or a LUT is transferred from the host system (PC/IPC) to the camera ('Write'). When clicking 'Save', the standard
Windows® dialog 'Save LUT to ...' is opened, and the user can name the desired .TXT file.
Note that the inscription and function of the 'Save/Write' button will not be visible and active, respectively, until the 'Read' or 'Load' button is pressed.
Figure 20 : The
Page 24 of 46 | KAMERA WERK DRESDEN GmbH |