The 'Look-up Table x' menu

This menu is used for loading one of the three user-specific look-up tables in the camera to the host system, and loading, or saving, user-specific look-up tables (LUT) from the host system (PC/IPC) to the camera.

The user can enter the desired LUT name in the 'Name' field. All upper-case and lower-case letters and numerals as well as the separating character '_' are available for the purpose.

The buttons under 'Actions' allow the user to choose from the following LUT functions:

Read The selected LUT is transferred from the camera to the host system (PC/IPC), and the function values are displayed under 'Lookup table contents'. By clicking button 'Save', the transferred LUT can be saved as a text file in the host system (PC/IPC).

Load A LUT (text file) in the host system is selected to be transferred to the camera. When the button is pressed, the standard

Windows® dialog 'Load LUT from ...' is opened, and the user can choose the desired file (in the

.TXT format). Clicking the 'Write' button transfers the selected LUT to the camera.

Save / Write A LUT transferred from the camera is saved as a text file in the host system LUT ('Save'), or a LUT is transferred from the host system (PC/IPC) to the camera ('Write'). When clicking 'Save', the standard

Windows® dialog 'Save LUT to ...' is opened, and the user can name the desired .TXT file.

Note that the inscription and function of the 'Save/Write' button will not be visible and active, respectively, until the 'Read' or 'Load' button is pressed.

Figure 20 : The 'Look-up table x' menu