Version 1.08 (04/07)Manual: CMOS Industrial Camera LOGLUX® i5
⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯
Technical specification
Technical data of the LOGLUX i5 CL (survey)
Sensor format: | 1280 x 1024 pixels | |
| (2/3 in. sensor diagonal) | |
| freely selectable ROI | |
Pixel size: | 6.7 x 6.7μm2 |
|
ADC resolution: | 10 bit greyscale value | |
Image transfer | Resolution | fps |
rate: | 1280 x 1024 | 36 |
| 1024 x 768 | 58 |
| 320 x 240 | 445 |
Shutter modes: | rolling shutter |
|
| central shutter | |
Dynamic range: | 64 dB linear, |
|
| > 100 dB in multiple | |
| integration slope mode | |
FPN: | < 0.2% RMS |
|
Sensitivity: | 8.46 V/(lx . s) |
|
| in visible light and NIR | |
| range (70 lx = 1 W/m2) | |
S/N ratio: | 1600 : 1 |
|
Spectral range : | 400...1000 nm | |
Configuration: | - 4 | |
| - bootable with initial settings |
Integral functions: test image, three
Interfaces: - CameraLink™(base)
-
-one 24VDC trigger port, electrically isolated
-two 24VDC/max. 500mA switchports
Power supply: | 18...35 VDC |
Power loss: | <2 W |
Temp. range: | 0...60°C (operation) |
Dimensions HxWxD | 54 x 46 x 82 |
(mm/without lens): |
|
Lens mount: | C mount |
Weight: | approx. 250g (without lens) |
Scope of delivery: | camera with LuxWare software and |
| manual (on |
Pin assignments of the LOGLUX® i5 CL
The mechanical and electrical parameters of the CameraLink™ connector ('DIGITAL OUT') correspond to the CameraLink™ standard specifications. More information can be found in the following documents and under www.ieee.org :
∙CameraLink™ Interface Standard Specification, Technical Communications, October 2000
∙CameraLink™ Technology Brief, Basler Vision Technologies, March 2001
Assignment of pins of the
Front view | Pin | Signal name | Function | |
| no. | |||
|
|
| ||
| 1 | +24V | 24V power supply | |
| 2 | Rx | Serial reception | |
| 3 | Tx | Serial transmission | |
| 4 | GND_pwr | Central ground (power | |
|
|
| supply) | |
| 5 | GND_if | Serial signal ground | |
| 6 | Ext_Trig_in | Trigger signal input | |
| 7 | GND_pwr | Central ground (trig./SW) | |
Fitting female connector (example): | 8 | Ext_SW_out1 | 1st switch signal output | |
9 | Ext_SW_out2 | 2nd switch signal output | ||
product name: | ||||
|
|
|
Pin assignment of the split cable for the LOGLUX® i5 CL
Power supply: | Binder | |
| Pin 1: +24VDC | Pin 2: GND |
Trigger input/ |
|
|
switch outputs: | Binder | |
| Pin 1: Trigger input | Pin 2: Switchport 0 Pin 3: Switchport 1 Pin 4 : GND |
Page 40 of 46 | KAMERA WERK DRESDEN GmbH |