Kenwood 144, 440 MHz TH-D7A instruction manual Short, Default, Parameter, Description, Persist

Models: 144 440 MHz TH-D7A TH-D7A

1 112
Download 112 pages 51.12 Kb
Page 110
Image 110
PERSIST

Command Name

Short

Default

Parameter

Description

 

 

 

 

 

PERSIST

PE

128

0 ~ 255

Specifies a parameter to calculate probability for the

PERSIST/SLOTTIME method.

 

 

 

 

 

 

 

 

 

PPERSIST

PP

ON

ON/ OFF

Causes the TNC to use the PERSIST/SLOTTIME method

when ON, or the DWAIT method when OFF.

 

 

 

 

 

 

 

 

 

RESET

RESET

Restores the default status for all the commands.

 

 

 

 

 

RESPTIME

RES

5

0 ~ 250

Specifies the acknowledgment packet transmission delay.

The unit of the parameter is 100 milliseconds.

 

 

 

 

 

 

 

 

 

RESTART

RESTART

Causes the TNC to function as if it is switched OFF then ON.

 

 

 

 

 

 

 

 

 

Specifies the number of transmission retries. If packets are

RETRY

RE

10

0 ~ 15

not correctly accepted while in connection, a connect request

 

 

 

 

is sent again after the specified number of retries.

 

 

 

 

 

SENDPAC

SE

$0D

0 ~ $7F

Specifies a character which forces a packet to be sent.

 

 

 

 

 

 

 

 

 

Specifies the period of random number generation intervals

SLOTTIME

SL

3

0 ~ 250

for the PERSIST/SLOTTIME method. The unit of the

 

 

 

 

parameter is 10 milliseconds.

 

 

 

 

 

TRACE

TRAC

OFF

ON/ OFF

When ON, causes the TNC to display all received packets in

their entirety.

 

 

 

 

 

 

 

 

 

TRIES

TRI

0

0 ~ 15

Specifies the number of transmission retries programmed in

the retry counter.

 

 

 

 

 

 

 

 

 

TXDELAY

TX

50

0 ~ 120

Specifies the time delay between PTT ON and start of

transmission. The unit of the parameter is 10 milliseconds.

 

 

 

 

 

 

 

 

 

 

 

 

Call1 (VIA

Specifies call signs to send a packet in Unprotocol mode.

UNPROTO

U

CQ

call2, call3, ...

Call1 is the call sign of the destination. Call2 to call9 are call

 

 

 

call9)

signs of stations to be digipeated through.

 

 

 

 

 

XFLOW

X

ON

ON/ OFF

Causes the TNC to perform software flow control when ON, or

hardware flow control when OFF.

 

 

 

 

 

 

 

 

 

102

Page 110
Image 110
Kenwood 144, 440 MHz TH-D7A instruction manual Short, Default, Parameter, Description, Persist