CHANGING FREQUENCY STEP SIZE

CHANGING FREQUENCY STEP SIZE

1Choosing the correct step size is essential in order to select your exact receive frequency using the Tuning

2control or [UP]/ [DWN]. The default step size on the

3VHF band is 5 kHz (TH-D7A) or 12.5 kHz (TH-D7E).

4The default on the UHF band is 25 kHz no matter which market version.

5

6

1 Press [A/B] to select band A or B.

• If necessary, press [F], [A/B] to recall the sub-band.

7

2 Press [F], [8] to select “F–8 (STEP)”.

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

STA CON PACKET96 BCONDUP

10

5

7

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

133 Press [UP]/ [DWN] to select the desired step size.

14

• The selectable step sizes are 5, 6.25, 10, 12.5, 15, 20,

15

25, 30, 50, and 100 kHz.

 

 

 

 

 

 

 

 

 

16

 

 

 

 

 

 

 

STA CON PACKET96 BCONDUP

17

 

 

 

 

 

 

 

5

7

9

 

 

 

 

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

20

214 Press [OK] to complete the setting.

22Note: Changing between step sizes may correct the displayed

frequency. For example, if 144.995 MHz is displayed with a 5 kHz step

23size selected, changing to a 12.5 kHz step size corrects the displayed frequency to 144.9875 MHz.

PROGRAMMABLE VFO

If you always check frequencies within a certain range, set upper and lower limits for frequencies that are selectable using the Tuning control or [UP]/ [DWN]. For example, if you select 145 MHz for the lower limit and 146 MHz for the upper limit, the tunable range will be from 145.000 MHz to 146.995 MHz.

1Press [A/B] to select band A or B.

If necessary, press [F], [A/B] to recall the sub-band.

2Press [VFO].

3Press [F], [7] to select “F–7 (PROGRAM VFO)”.

The current lower frequency limit blinks.

4Press [UP]/ [DWN] to select the desired lower frequency limit.

STA CON PACKET96 BCONDUP

5 7 9

5Press [OK].

• The current upper frequency limit blinks.

6Press [UP]/ [DWN] to select the desired upper frequency limit.

7Press [OK].

Note:

You cannot program the 100 kHz and subsequent digits.

The exact 100 kHz and subsequent digits of the upper limit depend on the frequency step size selected.