Kenwood 440 MHz TH-D7A, 144 instruction manual Transmitting A Message

Models: 144 440 MHz TH-D7A TH-D7A

1 112
Download 112 pages 51.12 Kb
Page 88
Image 88
TRANSMITTING A MESSAGE
STA CON
96 BCONDUP
For a message:

TRANSMITTING A MESSAGE

1When entry of a message (or bulletin) is completed, this transceiver automatically transmits it 5 times (max.) at

2intervals of 1 minute.

3

4

The transceiver repeats transmitting up to 5 times until a

5reception acknowledgment is returned.

6

7

5 7 9

8

9

10

11For a bulletin:

12The transceiver always repeat transmitting 5 times. A

13reception acknowledgment is not returned.

14

15

16

17

18

19

20

21

22

23

The table given on page 78 also shows indicators that appear for outgoing messages (or bulletins). “+” is assigned to messages (or bulletins) that have not yet been transmitted 5 times. You can also manually transmit all of those regardless of the 5-minute timer.

1Press [MSG].

2Press [UP]/ [DWN] to select “TRANSMIT”.

STA CON

96 BCONDUP

5 7 9

3Press [OK] to start transmitting.

• After transmission, the frequency display is restored.

80