4-7

Thumbscrew
Thumbscrew
Water Reservoir
Screw Water Recirculation
Pump Shield
Drain Cap
Spacer Bracket (Left Side) 18 Models
REMOVING THE WATER RECIRCULATION PUMP
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
1. Unplug ice maker or disconnect power.
2. Open the ice maker door.
3. Remove the ice from the storage bin.
4. Unscrew the drain cap from the reservoir,
drain the water, and replace the cap tightly.
5. Place a cloth in the drain hole to prevent
hardware from falling inside.
6. Remove the two thumbscrews from the
reservoir and remove the reservoir from
the unit.
3-Wire Connector
Water Fill Tube
Water Tube
3 Bracket Screws
7. Remove the hex-head screw from the
water recirculation pump shield and re-
move the shield (see the lower left photo).
8. Pull the water fill tube out of the slot in the
water recirculation pump bracket.
9. Remove the three hex-head screws from
the water recirculation pump bracket.
10. Disconnect the water recirculation pump
3-wire connector from the harness and
remove the pump.
11. Disconnect the water tube from the pump.