7-3FIRST 25 SECONDS OF DIAGNOSTICS/CLEAN MODE
ON/OFF/CLEAN
SWITCH
ELECTRONIC
CONTROL
WATER RECIRCULATING PUMP
CONDENSER FAN
Y
W/BK
YBU
OR
BU W
W
BK
BK
WATER INLET VALVE
HOT GAS SOLENOID
OVERLOAD
LED
COMPRESSOR RELAY
TN
PU
R
R
W
W
W
W

NOTE: Each relay on the electronic control board closes for five seconds in consecutive order.

The LED remains On through the entire Diagnostics cycle.

LAST 47 MINUTES OF DIAGNOSTICS/CLEAN MODE

ON/OFF/CLEAN

SWITCH

ELECTRONIC

CONTROL

WATER RECIRCULATING PUMP

Y
W/BK
YBU BU WBK
BK

HOT GAS SOLENOID

OVERLOAD

LED

COMPRESSOR RELAY

PU
R
R
W
W
W