6-9
°

Harvest Mode:

Compressor & Hot Gas Valve are energized
(3 minutes if evaporator thermistor is less
than 52°F or not sensed)
Move t his di rectio n if the
evap. ther mistor rem ains less
than 52°F and 1 m inute h as
elapsed
Compressor, Fan
& Water Valve
are energized
(1 minute)
1 minute has
elapse d
Unit leaves the
Freeze Mode
Evap. therm istor is greater
than or 3 minute s
have elapsed without
sensi ng th e evap . thermi stor
Check ice level
(The control reads
the bin thermistor)
Freeze Mode
(See page 6-8)
Idle Mode
(See page 6-7)
Bin is full
Bin is not full
Move t his di rectio n
if/wh en evap .
thermi stor is
greater th an
Harvest Fail
(See Failure Mode
on page 6-10)
12 minutes have elapsed.
The Compressor & Hot Gas Valve
will have been on a total of 16
minutes at this point
3 minutes have elapsed
with evap. thermistor
less than °
Evap. thermistor is greater
than °

NOTE: Each path is possible and acceptable at any temperature range. A typical operation

is shown below that may be found at a particular ambient temperature.

Cooler Ambients

(Below 90°F)

Warmer Ambients

(Above 90°F)

52°F
Compressor, Hot Gas &
Water Valves are
energized (time will be
0 to 1 minute maximum)
Compressor & Hot Gas Valve are energized
(12 minutes if evaporator thermistor remains
less than 52°F)