5-2
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
CUTTER GRIDRefer to page 4-2 for the procedure for servic-
ing the cutter grid.
1. Unplug ice maker or disconnect power.
2. Set the ohmmeter to the R x 1 scale.
3. Touch the ohmmeter test leads to the pins
of the cutter grid 2-wire connector. The
meter should indicate 4 to 5 Ω.
Refer to page 4-5 for the procedure for servic-
ing the cutter grid transformer.
1. Unplug ice maker or disconnect power.
2. Set the ohmmeter to the R x 1 scale.
3. Touch the ohmmeter test leads to the
primary terminals of the cutter grid trans-
former. The meter should indicate be-
tween 12 and 18 Ω.
4. Touch the ohmmeter test leads to the
secondary terminals of the cutter grid trans-
former. The meter should indicate less
than 1 Ω.
CUTTER GRID TRANSFORMERPrimary Secondary