5-4
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
HOT GAS VALVE SOLENOID
Refer to page 4-16 for the procedure for servic-
ing the hot gas valve solenoid.
1. Unplug ice maker or disconnect power.
2. Set the ohmmeter to the R x 1 scale.
3. Touch the ohmmeter test leads to the pins
of the hot gas valve solenoid 2-wire con-
nector. The meter should indicate between
365 and 390 .
Refer to page 4-15 for the procedure for servic-
ing the water inlet valve.
1. Unplug ice maker or disconnect power.
2. Set the ohmmeter to the R x 100 scale.
3. Touch the ohmmeter test leads to the
water inlet valve solenoid terminals. The
meter should indicate between 2650 and
2750 .
WATER INLET VALVE SOLENOID