4-9
10. Disconnect the inlet tube and the vent tube
from the internal drain pump.
12. Disconnect the wire connector from the
condenser fan motor.
13. Remove the four screws (two bottom and
two side) from the condenser fan motor
shroud. Slide the shroud assembly back
towards the compressor, and then lift and
remove the assembly from the unit.
11. Tilt the front of the cabinet up until you can
access the two side screws on the con-
denser fan motor shroud, and secure the
cabinet so that it cannot tip forward or
backward.
Disconnect Tubing
Internal Drain Pump
Tilt Cabinet Back
Prop Up Securely
Condenser Fan Motor Left Side Shroud Screw
Continued on the next page.
Condenser Fan Motor Bottom Shroud Screws
Motor Connector