4-8

REMOVING THE CONDENSER FAN MOTOR

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
1. Unplug ice maker or disconnect power.
2. Open the ice maker door.
3. Remove the ice from the storage bin.
4. Disconnect the water and drain lines from
the ice maker and remove the unit from its
installation.
5. Remove the four hex-head screws from
the front panel and remove the panel.
6. Remove the two 5/16 screws from the
front of the cabinet.
7. Disconnect the water outlet tubing from
the water valve.
8. Disconnect the electrical connectors from
the water inlet valve and hot gas valve
terminals.
Front Panel Screws
Screw Screw
Water Outlet Tubing
NOTE: If the unit you are servicing is equipped
with an internal drain pump, perform steps 9
and 10. If the unit does not have an internal
pump, skip those steps, and proceed to step 11
on the next page.
9. From the back of the unit, remove the four
screws from the unit compartment cover
and remove the cover.
Unit Compartment Cover
4 Screws
Electrical Connectors
Water Inlet Valve Hot Gas Valve