6-6

Flush Mode (5 minutes)

Water Valve
is energized
(2 minutes)
When On is selected
at the pushbutton switch

The Flush Mode begins every time the pushbutton switch is changed to “On” from

“Off” or “Clean.” This will be the initial time the unit is turned on, or when the unit is

turned on after the completion of a Clean Cycle, or (drain pump model only) when

operation resumes after the unit is shut down by the drain pump.

Recirc. Pump
is energized
(1 minute)
Water Valve
is energized
(2 minutes)
Idle Mode begins
(See page 6-7)
When 2 minutes
have elapsed
When 2 minutes
have elapsed
When 1 minute
has elapsed