6-2

TROUBLESHOOTING CHART
Problem Probable Cause Test Procedure-Action
No power at wall outlet Check circuit breaker/fuses
No power at drain pump
power outlet
Check for kinked drain hose,
blocked screen or blocked vent
outlet or hose.
Open selector switch Check for continuity from
terminals 1 - 2 on selector switch
Loose connections
at selector switch
or control board
Repair connections
No power through
power cord
Check continuity of power
cord and replace if open
Room temperature below
55°F (13°C)
Bin thermistor has unit shut off
Customer Instruction
Ice touching bin thermistor Normal operation
Water supply turned off Turn on water supply
Loose or missing
reservoir cap Tighten or replace
Water slide return tube
out of reservoir Reposition tube
Inlet tube out of position
and missing reservoir Reposition tube
Water inlet tube frozen
near evaporator Thaw and reposition tube
Defective inlet water valve Test and repair or replace
An ice slab only partially
released from evaporator
and water was bridged
down into the bin
Look for interference with
cutter grid and clean the
evaporator plate (see procedure
on page 8-1)
Will not make ice
Water reservoir is empty
Evaporator is cold with
thin or no ice slab
Will not run