Feeding documents that require special handling

Calibrating the scanner

The gap release lever allows you to manually adjust the space between the feed module and separation roller for documents that require special handling; i.e. documents that are badly torn. If you are in doubt about whether a damaged document can be transported through the scanner, use the gap release lever and manually feed the document. Using the scanner in continuous feed mode is recommended when handling special documents.

1.Press and hold the gap release lever — this provides clearance to ease document feeding.

2.Push the document into the elevator tray. If more than one document is to be scanned, feed them one at a time.

3.After the document(s) has been fed, release the gap release lever.

There are two types of calibration that can be performed on the i600/ i700 Series Scanners: Image calibration and Ultrasonics calibration.

Image calibration: optimizes the optical system in your scanner in order to achieve the best overall quality of scanned images. Frequent calibration is not needed or recommended.

IMPORTANT: If the White Background Accessory is installed, it must be replaced with the black background strip, and the scanner must be rebooted prior to calibration.

Ultrasonics calibration: ensures that the ultrasonics system that detects multi-feeds and document edges is properly adjusted for best performance. Frequent calibration is not needed or recommended.

A-61500 May 2010

3-11

Page 27
Image 27
Kodak 6J7611A manual Calibrating the scanner