Connecting the VP-747 Control Ports

7.3 Connecting the VP-747 to the Kramer VP-727T

To connect the VP-747to the Kramer VP-727TPresentation Switcher Control Panel1 via the mini XLR connector, as illustrated in, do the following:

Connect the “A” PIN on the TO CONTROLLER mini XLR connector of the VP-747to the A (+) PIN on the RS-485 rear panel port of the VP-727Tunit

Connect the “B” (-) PIN on the TO CONTROLLER mini XLR connector of the VP-747to the B (-) PIN on the RS-485 rear panel port of the VP-727Tunit

If shielded twisted pair cable is used, the shield may be connected to the “G” (Ground) PIN on one of the units

A

B

VP-727A

VP-747

 

G

VP-747 Mini

XLR Connector

VP-727T Side Panel

VP-727T

12V

Power Supply

Figure 8: Connecting the VP-747 to the VP-727T