Kramer Electronics VP-747 user manual Define the output Mode Setting

Models: VP-747

1 59
Download 59 pages 30.77 Kb
Page 33
Image 33

Operating the VP-747

Figure 13 and Table 7 define the output Mode Setting:

Figure 13: Output Mode Setting Screen

Table 7: Output Mode Functions

Setting

Function

Range

Default

Custom Output

Set custom values

Custom 1 to 4

 

HT

Horizontal total

 

1344

HW

Horizontal sync pulse width

 

136

HS

Horizontal active start point

 

296

HA

Horizontal active region

 

1024

HP

Horizontal polarity

 

 

VT

Vertical total

 

806

VW

Vertical sync pulse width

 

6

VS

Vertical active start point

 

35

VA

Vertical active region

 

768

VP

Vertical polarity

 

 

OCLK

Output clock

 

65

Save

Click to save the settings

 

 

Set Current

Import the values of the currently selected output

 

N/A

 

resolution into the User Mode Setting

 

 

30

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Page 33
Image 33
Kramer Electronics VP-747 user manual Define the output Mode Setting