VP-747 Communication Protocol

Control Type

Function

Param1

Param2

Param3

Param4

Description

Set

 

Get

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Preview Input

0

 

 

 

1

91

32 ~ (HS-48)

-

-

-

Setting User

 

 

 

 

 

 

 

 

 

 

 

Mode HW

 

 

 

 

 

 

 

 

 

 

 

Preview Input

0

 

 

 

1

92

80~(HT-HA-12)

-

-

-

Setting User

 

 

 

 

 

 

 

 

 

 

 

Mode HS

 

 

 

 

 

 

 

640~1920

 

 

 

Preview Input

0

 

 

 

1

93

-

-

-

Setting User

 

 

 

<= (HT-92)

 

 

 

 

 

 

 

 

 

 

Mode HA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0: -

 

 

 

Preview Input

0

 

 

 

1

94

-

-

-

Setting User

 

 

 

1: +

 

 

 

 

 

 

 

 

 

 

Mode HP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Preview Input

0

 

 

 

1

95

384~2047

-

-

-

Setting User

 

 

 

 

 

 

 

 

 

 

 

Mode VT

 

 

 

 

 

 

 

 

 

 

 

Preview Input

0

 

 

 

1

96

2~(HS-13)

-

-

-

Setting User

 

 

 

 

 

 

 

 

 

 

 

Mode VW

 

 

 

 

 

 

 

 

 

 

 

Preview Input

0

 

 

 

1

97

15~(VT-VA-1)

-

-

-

Setting User

 

 

 

 

 

 

 

 

 

 

 

Mode VS

 

 

 

 

 

 

 

480~1200

 

 

 

Preview Input

0

 

 

 

1

98

-

-

-

Setting User

 

 

 

<= (VT-16)

 

 

 

 

 

 

 

 

 

 

Mode VA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0: -

 

 

 

Preview Input

0

 

 

 

1

99

-

-

-

Setting User

 

 

 

1: +

 

 

 

 

 

 

 

 

 

 

Mode VP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25 ~ 165 (Integer

0 ~ 999

 

 

Preview Input

0

 

 

 

1

100

-

-

Setting User

 

 

 

Value)

(Decimal Value)

 

 

 

 

 

 

 

 

 

 

 

Mode OCLK

0

 

 

 

1

101

0:Off

-

-

-

Preview Input

 

 

 

1:On

Setting Enable

 

 

 

 

 

 

 

 

 

 

0

 

 

 

-

102

-

-

-

-

Preview Input

 

 

 

Setting User

 

 

 

 

 

 

 

 

 

 

 

Mode Save

 

 

 

 

 

 

 

0: Custom 1

 

 

 

 

0

 

 

 

1

103

1: Custom 2

-

-

-

Preview Custom

 

 

 

2: Custom 3

Output Target

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3: Custom 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Preview Output

0

 

 

 

1

104

512 ~ 3071

-

-

-

Setting User

 

 

 

 

 

 

 

 

 

 

 

Mode HT

 

 

 

 

 

 

 

 

 

 

 

Preview Output

0

 

 

 

1

105

32 ~ (HS-48)

-

-

-

Setting User

 

 

 

 

 

 

 

 

 

 

 

Mode HW

 

 

 

 

 

 

 

 

 

 

 

Preview Output

0

 

 

 

1

106

80~(HT-HA-12)

-

-

-

Setting User

 

 

 

 

 

 

 

 

 

 

 

Mode HS

 

 

 

 

 

 

 

 

 

 

 

Preview Output

0

 

 

 

1

107

640 ~ 1920

-

-

-

Setting User

 

 

 

 

 

 

 

 

 

 

 

Mode HA

 

 

 

 

 

 

 

0: -

 

 

 

Preview Output

0

 

 

 

1

108

-

-

-

Setting User

 

 

 

1: +

 

 

 

 

 

 

 

 

 

 

Mode HP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Preview Output

0

 

 

 

1

109

384~2047

-

-

-

Setting User

 

 

 

 

 

 

 

 

 

 

 

Mode VT

 

 

 

 

 

 

 

 

 

 

 

Preview Output

0

 

 

 

1

110

2~(HS-13)

-

-

-

Setting User

 

 

 

 

 

 

 

 

 

 

 

Mode VW

 

 

 

 

 

 

 

15~(VT-VA-1)

 

 

 

Preview Output

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

1

111

 

-

-

-

Setting User

 

 

 

 

 

 

 

 

 

 

 

Mode VS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 48
Image 48
Kramer Electronics user manual VP-747 Communication Protocol