Kramer Electronics user manual 11 VP-747 Communication Protocol

Models: VP-747

1 59
Download 59 pages 30.77 Kb
Page 43
Image 43

VP-747 Communication Protocol

11 VP-747 Communication Protocol

This section includes the Communication Protocol for the VP-747: Communication Confirm:

Send CR

Reply CR>

Set Command

Send YControl_TypeFunctionParamCR

Reply ZControl_TypeFunctionParamCR>

Get Command

Send YControl_TypeFunctionCR

Reply ZControl_TypeFunctionParamCR>

Example: set Preview Source Type of Current Channel = RGBHV

Send Y0430CR

Reply Z0430CR>

Example: get Preview Source Type of Current Channel

Send

Y143CR

Reply

Z1430CR >

: ASCII Code 0x20

CR : Ascii Code 0x0D

After set type Command setting, the system will respond with a string. Baud rate: 9600/115200bps, Data Bit: 8Bit, Parity: None, and Stop Bit: 1Bit. Table 14 defines the Set Commands:

40

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Page 43
Image 43
Kramer Electronics user manual 11 VP-747 Communication Protocol