5: Commands and Levels
XPort Pro Command Reference 102
<string> = string that may contain binary characters.
Within [] use binary decimal up to 255 or hex up to 0xFF.
command mode signon message <string>
Sets an ASCII sign-on message that is sent from the serial
port when the
device boots and when the line is in command mode.
<string> = text.
command mode signon message binary <string>
Sets a binary sign-on message that is sent from the serial
port when the
device boots and when the line is in command mode.
<string> = string that may contain binary characters.
Within [] use binary decimal up to 255 or hex up to 0xFF.
command mode wait time <milliseconds> Sets boot-up wait time for command mode serial string.
<milliseconds> = wait time.
configure current settings
Configures line with the current value of settings.
data bits 7
Uses seven bits for data on the line.
data bits 8
Uses eight bits for data on the line.
default baud rate
Restores the default speed of 9600 bits per second.
default data bits
Restores the default of eight data bits.
default flow control
Restores the default of no flow control.
default interface
Restores the default interface type to this line.
default parity
Restores the default of no parity.
default protocol
Restores the default protocol on the line.
default stop bits
Restores the default of one stop bit.
default threshold
Restores the factory default threshold.
default xoff char
Restores the default xoff character on this line.
default xon char
Restores the default xon character on this line.
exit
Exits to the enable level
flow control hardware
Uses hardware (RTS/CTS) flow control on the line.
flow control none
Does not provide flow control on the line.
flow control software
Uses software (xon/xoff characters) flow control on the
line.
gap timer
<milliseconds>
Sets the gap timer in milliseconds. If some data has been
received, it will
be forwarded after this time since the last character.
interface rs232
Sets the line interface to RS232.
interface rs485 full-duplex
Sets the line interface to RS485 in full-duplex mode.
interface rs485 half-duplex
Sets the line interface to RS485 in half-duplex mode.
kill session
Kills command mode session on the Line
line <line>
Enters the line level.
<line> = number of the line (serial port) to be configured.
lpd <line>
Enters the configure lpd level.
<line> = number of the line (lpd serial port) to be confi-
gured.
name <text>
Sets the name for this line.
no clear line counters
Restores the serial counters to the aggregate values.
no command mode
Disables command mode for the current line.
no command mode cp
Disables control of a CP to enter command mode.
no command mode serial string Prevents the user-defined serial boot string from being
used to enter
command mode in the CLI.