Accuracy

Characteristics

Standard

Standard

Measure time,

Measure time,

measuring

deviation,

typical [s]

maximum [s]

 

ISO 17123-4

 

 

Reflectorless

3 mm + 2 ppm

3 - 6

12

1.5 m - 500 m

 

 

 

 

 

 

 

Reflectorless

5 mm + 2 ppm

3 - 6

12

>500 m

 

 

 

 

 

 

 

Object in shade, sky overcast.

Beam interruptions, severe heat shimmer and moving objects within the beam path can result in deviations of the specified accuracy.

The display resolution is 0.1 mm.

Measuring system R100:

Special frequency system basis 100 MHz 1.5 m

Measuring system R300: System analyser basis 100 MHz - 150 MHz

Type:

Coaxial, visible red laser class 3R

Carrier wave:

670 nm

 

 