Check & Adjust

TPS1200

116

Step Description

1.Setup the instrument on a tripod (1).

2.Level up the instrument with the electronic level. SHIFT F12 to access STATUS Level & Laser Plummet.

3.PAGE (F6) to access the Laser Plummet page. Switch on the laser plummet.

)Inspection of the laser plummet should be carried out on a bright, smooth and horizontal surface, such like a sheet of paper.

4.Mark the centre of the red dot on the ground (2).

5.Slowly turn the instrument through 360°, carefully observing the move- ment of the red laser dot (3).

)The maximum diameter of the circular movement described by the centre of the laser point should not exceed 3 mm at a distance of 1.5 m.

6.IF the centre of the laser dot describes a perceptible circular movement or moves more than 3 mm away from the point which was first marked, an adjustment may be required. Inform your nearest Leica Geosystems authorized service workshop.

Page 116
Image 116
Leica user manual Check & Adjust TPS1200 116, Step Description