Technical Data

TPS1200

170

Atmospheric conditions

)

Accuracy

A:Strong haze, visibility 5 km; or strong sunlight, severe heat shimmer

B:Light haze, visibility about 20 km; or moderate sunlight, slight heat shimmer

C:Overcast, no haze, visibility about 40 km; no heat shimmer

Measurements can be made to reflector tapes over the entire range without external ancillary optics.

Accuracy refers to measurements to standard prisms.

EDM

Standard

Standard

Measurement

measuring

deviation,

deviation,

time, typical [s]

program

ISO 17123-4,

ISO 17123-4,

 

 

standard prism

tape

 

Standard

2 mm + 2 ppm

5 mm + 2 ppm

1.5

 

 

 

 

Fast

5 mm + 2 ppm

5 mm + 2 ppm

0.8

 

 

 

 

Tracking

5 mm + 2 ppm

5 mm + 2 ppm

< 0.15

 

 

 

 

Averaging

2 mm + 2 ppm

5 mm + 2 ppm

-

 

 

 

 

Beam interruptions, severe heat shimmer and moving objects within the beam path can result in deviations of the specified accuracy.

The display resolution is 0.1 mm.