￿Warning

￿Warning

Description

R100

R300

Maximum average radiant power

4.75 mW ± 5%

4.75 mW ± 5%

 

 

 

Maximum peak radiant power

59 mW ± 5%

59 mW ± 5%

 

 

 

Pulse duration

800 ps

800 ps

 

 

 

Pulse repetition frequency

100 MHz

100 MHz - 150 MHz

 

 

 

Beam divergence

0.15 mrad x 0.35 mrad

0.15 mrad x 0.5 mrad

 

 

 

 

 

 

For safety aspects direct intrabeam viewing should always be considered as hazardous.

Precautions:

Do not stare into the beam or direct it towards other people unnecessarily. These measures are also valid for the reflected beam.

Looking directly into the reflected laser beam could be dangerous to the eyes when the laser beam is aimed at areas that reflect like a mirror or emit reflections unex- pectedly, for example prisms, mirrors, metallic surfaces or windows.

Precautions:

Do not aim at areas that are essentially reflective, such as a mirror, or which could emit unwanted reflections.

Safety Directions

TPS1200

143

Page 143
Image 143
Leica user manual Description R100 R300, Safety Directions TPS1200 143