CLEARANCE ON ALL SIDES

MINIMUM CLEARANCE

ABOVE UNIT

6 (152)

ACCESS PANEL

CONTROL PANEL ACCESS

LOCATION 30 (762)

12 (305)

 

 

LINE SET

36 (914)

CONNECTIONS

NOTES:

SClearance to one of the other three sides must be 36 inches (914mm).

SClearance to one of the remaining two sides may be 12 inches (305mm) and the final side may be 6 inches (152mm).

48 (1219)

MINIMUM CLEARANCE BETWEEN

TWO UNITS

24 (610)

ACCESS PANEL

LINE SET

CONNECTIONS

REAR VIEW OF UNIT

Figure 3. Installation Clearances

New Outdoor Unit Placement

property, not from the installation property. Install the

unit as far as possible from the property line.

CAUTION

In order to avoid injury, take proper precaution when lifting heavy objects.

See Unit Dimensions on page 3 for sizing mounting slab, platforms or supports. Refer to Figure 3 for mandatory installation clearance requirements.

POSITIONING CONSIDERATIONS

Consider the following when positioning the unit:

SSome localities are adopting sound ordinances based on the unit’s sound level registered from the adjacent

SWhen possible, do not install the unit directly outside a window. Glass has a very high level of sound transmission. For proper placement of unit in relation to a window see the provided illustration in Figure 4, Detail A.

PLACING UNIT ON SLAB

When installing unit at grade level, the top of the slab should be high enough above grade so that water from higher ground will not collect around the unit. The slab should have a slope tolerance as described in Figure 4, Detail B.

NOTE If necessary for stability, anchor unit to slab as described in Figure 4, Detail D.