XC17 Start−Up and Performance Checklist
Suction Pressure: | Liquid Pressure: |
|
|
|
|
| |||
Supply Air Temperature: |
|
| Ambient Temperature: | Return Air: Temperature: |
|
| |||
|
|
|
|
|
|
| |||
System Refrigerant Charge (Refer to manufacturer’s information on unit or installation instructions for required subcooling and approach | |||||||||
temperatures.) |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| |||
Subcooling: |
|
| A | B | = | SUBCOOLING | |||
| Saturated Condensing Temperature (A) |
|
|
|
| ||||
|
| minus Liquid Line Temperature (B) |
|
|
|
| |||
|
|
|
|
|
|
| |||
Approach: |
|
| A | B | = | APPROACH | |||
|
| Liquid Line Temperature (A) |
|
|
|
| |||
|
| minus Outdoor Air Temperature (B) |
|
|
|
| |||
|
|
|
|
|
|
| |||
Indoor Coil Temperature Drop (18 to 22°F) |
|
| A | B | = | COIL TEMP DROP |
Return Air Temperature (A) minus Supply Air Temperature (B)
Page 49
XC17 SERIES