Table 10. Compressor LED Alert Codes
Outdoor Main |
|
|
|
|
|
| ||
Control LEDs |
| Possible |
|
|
|
| ||
|
| Condition | Solution | Clearing Status | ||||
DS15 | DS13 | Cause(s) | ||||||
|
|
|
|
| ||||
|
|
|
|
|
| |||
Yellow | Red |
|
|
|
|
|
| |
|
|
|
|
|
|
| ||
|
|
|
| 1 | Compressor protector is open. |
| ||
|
|
|
|
| S Check for high head pressure |
| ||
|
|
| Thermostat |
| S Check compressor supply voltage | Clears the error after current | ||
|
|
| 2 |
|
| |||
|
| Compressor | demand signal Y1 | Outdoor unit power disconnect is open. | is sensed in the run and | |||
OFF | ON | Internal | is present, but | 3 | Compressor circuit breaker or fuse(s) is open. | start winding for two | ||
|
| Overload Trip | compressor not | 4 | Broken wire or connector is not making contact. | seconds, service removed | ||
|
|
| running | 5 | Low or high pressure switch open if present in the | or power reset. | ||
|
|
|
|
| ||||
|
|
|
|
| system. |
| ||
|
|
|
| 6 | Compressor contactor has failed to close. |
| ||
|
|
|
|
|
|
| ||
|
|
|
| 1 | Low refrigerant charge. |
| ||
|
|
|
| 2 | Evaporator blower is not running. |
| ||
|
|
|
|
| S Check blower relay coil and contacts |
| ||
|
|
|
|
| S Check blower motor capacitor |
| ||
|
|
|
|
| S Check blower motor for failure or blockage |
| ||
|
|
|
|
| S Check evaporator blower wiring and connectors |
| ||
|
|
|
|
| S Check indoor blower control |
| ||
|
|
|
|
| S Check thermostat wiring for open circuit |
| ||
|
|
|
| 3 | Evaporator coil is frozen. |
| ||
|
|
|
|
| S Check for low suction pressure |
| ||
|
|
|
|
| S Check for excessively low thermostat setting |
| ||
1 Flashes |
|
| Compressor is |
| S Check evaporator airflow (coil blockages or return | Clears the error after 30 | ||
then | OFF | Long run time. | running extremely |
|
| air filter) | consecutive normal run | |
Pause |
|
| long run cycles. |
| S Check ductwork or registers for blockage. | cycles, or after power reset. | ||
|
|
|
|
|
| |||
|
|
|
| 4 | Faulty metering device. |
| ||
|
|
|
|
| S Check TXV bulb installation (size, location and |
| ||
|
|
|
|
|
| contact) |
| |
|
|
|
|
| S Check if TXV/fixed orifice is stuck closed or de- |
| ||
|
|
|
|
|
| fective |
| |
|
|
|
| 5 | Condenser coil is dirty. |
| ||
|
|
|
| 6 | Liquid line restriction (filter drier blocked if present). |
| ||
|
|
|
| 7 | Thermostat is malfunctioning. |
| ||
|
|
|
|
| S Check thermostat sub−base or wiring for short cir- |
| ||
|
|
|
|
|
| cuit |
| |
|
|
|
|
| S Check thermostat installation (location and level) |
| ||
|
|
|
|
|
|
| ||
|
|
|
| 1 | High head pressure. |
| ||
|
|
|
|
| S Check high pressure switch if present in system |
| ||
|
|
|
|
| S Check if system is overcharged with refrigerant |
| ||
|
|
| Indicates the |
| S Check for non−condensable in system |
| ||
2 Flashes |
| System | compressor | 2 | Condenser coil poor air circulation (dirty, blocked, | Clears after four | ||
then | OFF | protector is open |
| damaged). | consecutive normal | |||
Pressure Trip | or missing supply |
| compressor run cycles, or | |||||
Pause |
| 3 | Condenser fan is not running. | |||||
|
| power to the | after power reset. | |||||
|
|
|
|
|
| |||
|
|
| compressor. |
| S | Check fan capacitor |
| |
|
|
|
|
| S Check fan wiring and connectors |
| ||
|
|
|
|
| S Check fan motor for failure or blockage |
| ||
|
|
|
| 4 | Return air duct has substantial leakage. |
| ||
|
|
|
|
|
|
| ||
3 Flashes |
|
| Compressor is | 1 | Thermostat demand signal is intermittent. | Clears after four | ||
|
|
|
|
| ||||
|
| 2 | Time delay relay or Main Control is defective. | consecutive normal | ||||
then | OFF | Short Cycling | running less than | |||||
3 | If high pressure switch is present, see Flash Code 2 | compressor run cycles, or | ||||||
Pause |
|
| three minutes. | |||||
|
|
| information. | after power reset. | ||||
|
|
|
|
| ||||
|
|
|
|
|
| |||
|
|
|
|
|
|
| ||
|
|
| Compressor has | 1 | Run capacitor has failed. |
| ||
|
|
| a locked out due | 2 | Low line voltage (contact utility if voltage at disconnect |
| ||
4 Flashes |
|
| to run capacitor |
| is low). | Clears after power reset or | ||
then | OFF | Locked Rotor | short, bearings |
| four normal compressor | |||
| S | Check wiring connections | ||||||
Pause. |
|
| are seized, ex- |
| cycles. | |||
|
| 3 | Excessive liquid refrigerant in the compressor. | |||||
|
|
| cessive liquid re- |
| ||||
|
|
|
|
|
|
| ||
|
|
| frigerant. | 4 | Compressor bearings are seized. |
| ||
|
|
|
|
|
|
|
|
Page 37
XC17 SERIES