Lennox International Inc Dave Lennox Signature Collection XC17 Air Conditioner Detail A, Detail B

Models: Dave Lennox Signature Collection XC17 Air Conditioner 506510-01

1 49
Download 49 pages 11.15 Kb
Page 9
Image 9
DETAIL A

DETAIL A

INSTALL UNIT AWAY FROM WINDOWS

TWO 90° ELBOWS INSTALLED IN LINE SET WILL

REDUCE LINE SET VIBRATION.

Outside Unit Placement

DETAIL B

INSTALL UNIT LEVEL OR, IF ON A SLOPE, MAINTAIN SLOPE TOLERANCE OF 2 DEGREES (OR 2 INCHES PER 5 FEET [50 MM PER 1.5 M]) AWAY FROM BUILDING STRUCTURE.

BUILDING

STRUCTURE

MOUNTING

SLAB

GROUND LEVEL

Slab Mounting at Ground Level

DETAIL C

BASE

DETAIL D

Slab Side Mounting

#10 1/2" LONG SELF−DRILLING SHEET METAL SCREWS

STABILIZING BRACKET (18 GAUGE

METAL

REQUIRED)

#10 1−1/4" LONG HEX HD SCREW AND FLAT WASHER Outside Unit PlacementDETAIL BSlab Mounting at Ground Level

CONCRETE SLAB

ANCHORS (HOLE DRILL 1/4")

WOOD OR PLASTIC SLAB ANCHOR (HOLE DRILL 1/8")

DETAIL C COIL

BASE PAN

CORNER POST

LEG DETAIL

2" (50.8MM) SCH 40 FEMALE THREADED ADAPTER

2" (50.8MM) SCH 40 MALE THREADED ADAPTER

Use additional 2" SCH 40 male threaded adapters which can be threaded into the female threaded adapters to make additional adjustments to the level of the unit.

Elevated Slab Mounting using Feet

Extenders

 

MINIMUM ONE

Deck Top Mounting

PER SIDE

STABILIZING BRACKET (18 GAUGE METAL

2" (50.8MM) WIDTH; HEIGHT AS

REQUIRED); BEND TO FORM RIGHT ANGLE

 

FOR EXTRA

SAME FASTENERS AS

STABILITY

SLAB SIDE MOUNTING.

 

ONE BRACKET PER SIDE (MIN.); FOR EXTRA STABILITY, TWO

BRACKETS PER SIDE, 2" (50.8MM) FROM EACH CORNER.

Stabilizing Unit on Uneven Surfaces

IMPORTANT To help stabilize an outdoor unit, some installations may require strap- ping the unit to the pad using brackets and anchors commonly available in the market- place.

Figure 4. Placement, Slab Mounting and Stabilizing Unit

Page 9

XC17 SERIES

Page 9
Image 9
Lennox International Inc Dave Lennox Signature Collection XC17 Air Conditioner Detail A, Detail B, Detail C, Detail D