Lenovo 6445, 6447, 6446, 6444 manual Remove the cover 4. Remove the PCI riser-card assembly

Models: 6445 6444 6446 6447

1 112
Download 112 pages 28.39 Kb
Page 42
Image 42
3.Remove the cover.

1

Retainer bracket

3

Remote Supervisor Adapter II

 

 

 

SlimLine

2

Connector

4

Latch bracket

To install a Remote Supervisor Adapter II SlimLine, complete the following steps:

1.Read the safety information that begins on page v and “Installationguidelines” on page 7.

2.Turn off the server and peripheral devices and disconnect all power cords and external cables.

Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply.

3.Remove the cover.

4.Remove the PCI riser-card assembly.

5.Align the keys on the Remote Supervisor Adapter II SlimLine connector with the connector on the system board.

6.Slip the free end of the Remote Supervisor Adapter II SlimLine under the tab on the retainer bracket, aligning the holes in the adapter with the posts on the retainer bracket and latch bracket; then, press the adapter into the connector on the system board and make sure that all tabs on the latch bracket secure the adapter in place.

7.Replace the PCI riser-card assembly.

See the documentation that comes with the Remote Supervisor Adapter II SlimLine for information about installing the firmware and configuring the adapter. Create a backup copy of the configuration so that if you have to replace the adapter in the future, you can restore the configuration.

If you have other optional devices to install or remove, do so now. Otherwise, go to “Completingthe installation” on page 30.

28ThinkServer RD120 Types 6444, 6445, 6446, and 6447: Installation Guide

Page 42
Image 42
Lenovo 6445, 6447, 6446, 6444 manual Remove the cover 4. Remove the PCI riser-card assembly