Image 89
Serial port problems

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee the parts listing in the Hardware Maintenance Manual to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Symptom

Action

 

 

The server does not turn off.

1. Turn off the server by pressing the power-control button for 5 seconds.

 

 

2. Restart the server.

 

3. If the server fails POST and the power-control button does not work, disconnect

 

the power cord for 20 seconds; then, reconnect the power cord and restart the

 

server.

 

Attention: In a dc power environment, only trained service personnel other

 

than Lenovo service technicians are authorized to connect or disconnect power

 

to the dc power supply. See the documentation that comes with each dc power

 

supply.

 

4. If the problem remains, suspect the system board.

 

 

The OVER SPEC LED on the

See the power troubleshooting table in the Hardware Maintenance Manual or call

light path diagnostics panel is

for service.

lit, and the one of the power

 

channel LEDs on the system

 

board is lit.

 

 

 

The server unexpectedly shuts

See “Solvingundetermined problems” in the Hardware Maintenance Manual.

down, and the LEDs on the

 

operator information panel are

 

not lit.

 

 

 

Serial port problems

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee the parts listing in the Hardware Maintenance Manual to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Symptom

Action

 

 

 

The number of serial ports that

1.

Make sure that:

are identified by the operating

 

v Each port is assigned a unique address in the Configuration/Setup Utility

system is less than the number

 

program and none of the serial ports is disabled.

of installed serial ports.

 

 

v The serial-port adapter (if one is present) is seated correctly.

 

2.

Reseat the serial port adapter, if one is present.

 

3.

Replace the serial port adapter, if one is present.

 

 

 

Chapter 5. Solving problems 75

Page 89
Image 89
Lenovo 6446, 6447, 6445, 6444 manual Serial port problems