1 | RAID controller | 4 | Battery mounting tabs |
2 | Battery cable | 5 | Battery mounting clips |
3 | Battery | 6 | Battery cable connector |
9.Turn the new
10.Firmly press the
Note: If there is a gap between the controller and the retaining clips, the controller has not been correctly installed. In this case, open the retaining clips and remove the controller; then, reinsert the controller.
11.Remove the battery from the
12.Slide the battery mounting tabs into the battery mounting clips on the server wall that is next to the ServeRAID SAS controller connector.
13.Connect the battery to the
14.Replace the air baffle over the DIMMs. See the User Guide for more information.
15.Replace the
If you have other optional devices to install or remove, do so now. Otherwise, go to “Completingthe installation.”
Notes:
1.When you restart the server for the first time after you install a
Important: You must allow the initialization process to be completed. If you do not, the battery pack will not work, and the server might not start.
The battery comes partially charged, at 30% or less of capacity. Run the server for 4 to 6 hours to fully charge the controller battery. The LED just above the battery on the controller remains lit until the battery is fully charged.
Until the battery is fully charged, the controller firmware sets the controller cache to
2.When you restart the server, you will be given the opportunity to import the existing RAID configuration to the new ServeRAID SAS controller.
Completing the installation
To complete the installation, complete the following steps:
1.Install the cover. See “Installingthe cover” on page 31 for more information.
2.Install the server in the rack cabinet. See the Rack Installation Instructions that come with the server for detailed information about how to install the server in a rack cabinet.
30ThinkServer RD120 Types 6444, 6445, 6446, and 6447: Installation Guide