Intermittent problems

Intermittent problems

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee the parts listing in the Hardware Maintenance Manual to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Symptom

Action

 

 

A problem occurs only

1. Make sure that:

occasionally and is difficult to

v All cables and cords are connected securely to the rear of the server and

diagnose.

attached devices.

 

 

Attention: In a dc power environment, only trained service personnel

 

other than Lenovo service technicians are authorized to connect or

 

disconnect power to the dc power supply. See the documentation that comes

 

with each dc power supply.

 

v When the server is turned on, air is flowing from the fan grille. If there is no

 

airflow, the fans are not working. This can cause the server to overheat and

 

shut down.

 

2. Check the system event/error log or BMC system event log (see “ErrorLogs” in

 

the Hardware Maintenance Manual).

 

 

The server resets (restarts)

1. If the reset occurs during POST and the POST watchdog timer is enabled (click

occasionally

Advanced Setup --> Baseboard Management Controller (BMC) Setting -->

 

 

BMC Post Watchdog in the Configuration/Setup Utility program to see the

 

POST watchdog setting), make sure that sufficient time is allowed in the

 

watchdog timeout value (BMC POST Watchdog Timeout). See the User Guide

 

for information about the settings in the Configuration/Setup Utility program.

 

If the server continues to reset during POST, see the “POST”and “Diagnostic

 

programs” sections in the Hardware Maintenance Manual.

 

2. If the reset occurs after the operating system starts, disable any automatic

 

server restart (ASR) utilities, such as the IBM Automatic Server Restart IPMI

 

Application for Windows, or ASR devices that may be installed.

 

Note: ASR utilities operate as operating-system utilities and are related to the

 

IPMI device driver.

 

If the reset continues to occur after the operating system starts, the operating

 

system might have a problem; see “Softwareproblems” on page 76.

 

3. If neither condition applies, check the system event/error log or BMC system

 

event log (see “ErrorLogs” in the Hardware Maintenance Manual).

 

 