vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee the parts listing in the Hardware Maintenance Manual to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Symptom

Action

 

 

The power-control button does

1. Make sure that:

not work, and the reset button

v The power cords are correctly connected to the server and to a working

does work (the server does not

power source.

start).

Attention: In a dc power environment, only trained service personnel

Note: The power-control button

other than Lenovo service technicians are authorized to connect or

will not function until 20

disconnect power to the dc power supply. See the documentation that comes

seconds after the server has

with each dc power supply.

been connected to power.

v The type of memory that is installed is correct.

 

 

v The LEDs on the power supply do not indicate a problem.

 

v The microprocessors are installed in the correct sequence.

 

2. Make sure that the power-control button and the reset button are working

 

correctly:

 

Attention: In a dc power environment, only trained service personnel other

 

than Lenovo service technicians are authorized to connect or disconnect power

 

to the dc power supply. See the documentation that comes with each dc power

 

supply.

 

a. Disconnect the server power cords.

 

b. Reseat the operator information panel assembly cable.

 

c. Reconnect the power cords.

 

d. Press the power-control button to restart the server. If the button does not

 

work, replace the operator information panel assembly.

 

e. Press the reset button (on the light path diagnostics panel) to restart the

 

server. If the button does not work, replace the operator information panel

 

assembly.

 

3. If you just installed an optional device, remove it, and restart the server. If the

 

server now starts, you might have installed more devices than the power supply

 

supports.

 

4. Reseat the power backplane and restart the server.

 

5. Replace the power backplane and restart the server.

 

6. Replace the following components one at a time, in the order shown, restarting

 

the server each time:

 

a. Power supplies

 

Attention: In a dc power environment, only trained service personnel

 

other than Lenovo service technicians are authorized to connect or

 

disconnect power to the dc power supply and to remove and install the dc

 

power supply. See the documentation that comes with each dc power

 

supply.

 

b. (Trained service technician only) System board

 

7. See “Solvingpower problems” and “Solvingundetermined problems” in the

 

Hardware Maintenance Manual.

 

 