To run ServeRAID Manager in Startable CD mode, turn on the server; then, insert the CD into the
In the Configuration wizard, you can select express configuration or custom configuration. Express configuration automatically configures the controller by grouping the first two physical drives in the ServeRAID Manager tree into an array and creating a RAID
Using express configuration: To use express configuration, complete the following steps:
1.In the ServeRAID Manager tree, click the controller.
2.Click Express configuration.
3.Click Next.
4.In the “Configurationsummary” window, review the information. To change the configuration, click Modify arrays.
5.Click Apply; when you are asked whether you want to apply the new configuration, click Yes. The configuration is saved in the controller and in the physical drives.
6.Exit from ServeRAID Manager and remove the CD from the
7.Restart the server.
Using custom configuration: To use custom configuration, complete the following steps:
1.In the ServeRAID Manager tree, click the controller.
2.Click Custom configuration.
3.Click Next.
4.In the “Createarrays” window, from the list of ready drives, select the drives that you want to group into the array.
5.Click the (Add selected drives) icon to add the drives to the array.
6.If you want to configure a
a.Click the Spares tab.
b.Select the physical drive that you want to designate as the
7.Click Next.
8.Review the information in the “Configurationsummary” window. To change the configuration, click Back.
9.Click Apply; when you are asked whether you want to apply the new configuration, click Yes. The configuration is saved in the controller and in the physical drives.
10.Exit from ServeRAID Manager and remove the CD from the
11.Restart the server.
Viewing the configuration
You can use ServeRAID Manager to view information about RAID controllers and the RAID subsystem (such as arrays, logical drives,
46ThinkServer RD120 Types 6444, 6445, 6446, and 6447: Installation Guide