General problems

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee the parts listing in the Hardware Maintenance Manual to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Symptom

Action

 

 

 

The CD-RW/DVD drive tray is

1.

Make sure that the server is turned on.

not working.

2.

Insert the end of a straightened paper clip into the manual tray-release

 

 

 

opening.

 

3.

Reseat the CD-RW/DVD drive.

 

4.

Replace the CD-RW/DVD drive.

 

 

 

General problems

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee the parts listing in the Hardware Maintenance Manual to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Symptom

Action

 

 

A cover lock is broken, an LED

If the part is a CRU, replace it. If the part is a FRU, the part must be replaced by a

is not working, or a similar

trained service technician.

problem has occurred.

 

 

 

Hard disk drive problems

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee the parts listing in the Hardware Maintenance Manual to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Symptom

Action

 

 

Not all drives are recognized by

Remove the drive that is indicated by the diagnostic tests; then, run the hard disk

the hard disk drive diagnostic

drive diagnostic test again. If the remaining drives are recognized, replace the drive

test (the Fixed Disk test).

that you removed with a new one.

 

 

The server stops responding

Remove the hard disk drive that was being tested when the server stopped

during the hard disk drive

responding, and run the diagnostic test again. If the hard disk drive diagnostic test

diagnostic test.

runs successfully, replace the drive that you removed with a new one.

 

 

A hard disk drive was not

Reseat all hard disk drives and cables; then, run the hard disk drive diagnostic

detected while the operating

tests again.

system was being started.

 

 

 

A hard disk drive passes the

Run the diagnostic SCSI Attached Disk Test.

diagnostic Fixed Disk Test, but

 

the problem remains.

 

 

 

66ThinkServer RD120 Types 6444, 6445, 6446, and 6447: Installation Guide

Page 80
Image 80
Lenovo 6447, 6446, 6445, 6444 manual General problems, Hard disk drive problems