Installing the OSA SMBridge management utility program

Original bootcfg program output

Boot Loader Settings

----------------------------

timeout: 30

default: multi(0)disk(0)rdisk(0)partition(1)\WINDOWS Boot Entries

----------------

Boot entry ID: 1

OS Friendly Name: Windows Server 2003, Standard

Path: multi(0)disk(0)rdisk(0)partition(1)\WINDOWS

OS Load Options: /fastdetect

Modified bootcfg program output

Boot Loader Settings

----------------------------

timeout: 30

default: multi(0)disk(0)rdisk(0)partition(1)\WINDOWS

redirect: COM1

redirectbaudrate: 19200 Boot Entries

----------------

Boot entry ID: 1

OS Friendly Name: Windows Server 2003, Standard

Path: multi(0)disk(0)rdisk(0)partition(1)\WINDOWS

OS Load Options: /fastdetect /redirect

You must restart the Windows 2003 operating system after you complete this procedure for the changes to take effect and to enable SOL.

Installing the OSA SMBridge management utility program

Important: To obtain maximum benefit from the OSA SMBridge management utility program, install and load the program before problems occur.

To install the OSA SMBridge management utility program on a server running a

Windows operating system, complete the following steps:

1.Go to http://www.lenovo.com/support/ and download the utility program and create the OSA BMC Management Utility CD.

2.Insert the OSA BMC Management Utility CD into the drive. The InstallShield wizard starts, and a window similar to that shown in the following illustration opens.

56ThinkServer RD120 Types 6444, 6445, 6446, and 6447: Installation Guide