Microprocessor problems

Microprocessor problems

vFollow the suggested actions in the order in which they are listed in the Action column until the problem is solved.

vSee the parts listing in the Hardware Maintenance Manual to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU).

vIf an action step is preceded by “(Trained service technician only),” that step must be performed only by a trained service technician.

Symptom

Action

 

 

 

The server emits a continuous

1.

Correct any errors that are indicated by the LEDs (see “Lightpath diagnostics

beep during POST, indicating

 

LEDs” in the Hardware Maintenance Manual).

that the microprocessor is not

 

2.

Make sure that the server supports all the microprocessors and that the

working correctly.

 

microprocessors match in speed and cache size.

 

 

 

3.

(Trained service technician only) Make sure that microprocessor 1 is seated

 

 

correctly.

 

4.

Reseat the following components:

 

 

a. (Trained service technician only) Microprocessors

 

 

b. VRM, if microprocessor 2 is installed

 

5.

(Trained service technician only) Replace the microprocessors.

 

 

 

70ThinkServer RD120 Types 6444, 6445, 6446, and 6447: Installation Guide