Lenovo RD120 manual Replacing the RAID SAS controller

Models: RD120

1 118
Download 118 pages 33.27 Kb
Page 59
Image 59
Replacing the RAID SAS controller

Replacing the RAID SAS controller

A ServeRAID SAS controller can be installed only in a dedicated slot on the system board. The server comes with a ServeRAID-8k-l SAS Controller installed.

Note: The ServeRAID-8k-l SAS Controller does not have a battery.

To replace the ServeRAID-8k-l SAS Controller with a ServeRAID-8k SAS Controller, complete the following steps:

1.Read the safety information that begins on page v and “Installation guidelines” on page 29.

2.Turn off the server and peripheral devices and disconnect all power cords and external cables (see “Turning off the server” on page 12).

Attention: In a dc power environment, only trained service personnel other than Lenovo service technicians are authorized to connect or disconnect power to the dc power supply. See the documentation that comes with each dc power supply.

3.Remove the cover (see “Removing the cover” on page 31).

4.Remove the riser-card assembly and the air baffle over the DIMMs (see “Removing the DIMM air baffle” on page 37).

5.Locate the ServeRAID-8k-l SAS controller on the system board (see “System-boardoptional-device connectors” on page 18).

Attention: To avoid breaking the retaining clips or damaging the connectors, handle the clips gently.

6.Open the retaining clip on each end of the connector.

7.Lift the ServeRAID-8k-l SAS controller out of the connector.

8.Touch the static-protective package that contains the new ServeRAID-8k SAS controller to any unpainted metal surface on the server. Then, remove the ServeRAID-8k SAS controller from the package.

Chapter 2. Installing optional devices 45