NORMAL OPERATING PRESSURES

NORMAL OPERATING PRESSURES

Use the following tables to perform maintenance checks; it is not a procedure for charging the system. Minor variations in these pressures may be due to differences in installations. Significant deviations could mean that the system is not properly charged or that a problem exists with some component in the system.

Typical pressures only, expressed in psig (liquid +/− 10 and vapor +/− 5 psig); matched indoor component (air handler or coil), indoor air quality, and indoor load will cause the pressures to vary.

Table 7. Normal Operating Pressures*

Normal Operating Pressures − Cooling

XP16

−024

−036

−048

−060

 

 

 

 

 

 

 

 

 

°F

Liq

Vap

Liq

Vap

Liq

Vap

Liq

Vap

(°C)**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

First Stage (Low Capacity) Pressure

 

 

 

 

 

 

 

 

 

 

 

65

226

144

220

141

224

143

230

137

(18.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

260

145

254

144

259

143

267

139

(23.9)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

301

148

295

148

302

147

311

141

(29.4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

95

346

151

340

150

346

149

357

144

(35.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

105

396

153

389

153

396

152

398

147

(40.6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115

451

156

444

156

450

155

453

149

(46.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Second Stage (High Capacity) Pressure

 

 

 

 

 

 

 

 

 

 

 

65

241

140

232

129

238

138

232

131

(18.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

279

142

269

136

278

140

276

133

(23.9)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

321

144

312

140

321

142

320

136

(29.4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

95

369

146

346

142

372

144

367

138

(35.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

105

421

148

409

145

424

147

421

141

(40.6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115

480

151

465

148

481

149

479

144

(46.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal Operating Pressures − Heating

 

 

 

 

 

 

 

 

 

First Stage (Low Capacity) Pressure

 

 

 

 

 

 

 

 

 

 

 

50

312

112

350

115

336

114

385

108

(10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

330

130

372

136

363

135

414

126

(15.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Second Stage (High Capacity) Pressure

 

 

 

 

 

 

 

 

 

 

 

20

299

64

321

61

289

57

332

59

(−7.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

312

79

347

74

294

69

349

67

(−1.0)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40

325

93

367

90

321

80

361

75

(4.4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50

344

110

387

110

341

110

383

85

(10)

 

 

 

 

 

 

 

 

60

(15.5) 358 128 395 131 361 128 425 122

** Temperature of air entering outdoor coil.

TEMPERATURE PRESSURES

Compute subcooling by determining saturated condensing temperature from temperature pressure chart. Subtract from liquid temperature entering TXV.

Table 8. HFC−410A Temperature (°F) −

Pressure (Psig)

°F

Psig

°F

Psig

°F

Psig

°F

Psig

 

 

 

 

 

 

 

 

32

100.8

63

178.5

94

290.8

125

445.9

 

 

 

 

 

 

 

 

33

102.9

64

181.6

95

295.1

126

451.8

 

 

 

 

 

 

 

 

34

105.0

65

184.3

96

299.4

127

457.6

 

 

 

 

 

 

 

 

35

107.1

66

187.7

97

303.8

128

463.5

 

 

 

 

 

 

 

 

36

109.2

67

190.9

98

308.2

129

469.5

 

 

 

 

 

 

 

 

37

111.4

68

194.1

99

312.7

130

475.6

 

 

 

 

 

 

 

 

38

113.6

69

197.3

100

317.2

131

481.6

 

 

 

 

 

 

 

 

39

115.8

70

200.6

101

321.8

132

487.8

 

 

 

 

 

 

 

 

40

118.0

71

203.9

102

326.4

133

494.0

 

 

 

 

 

 

 

 

41

120.3

72

207.2

103

331.0

134

500.2

 

 

 

 

 

 

 

 

42

122.6

73

210.6

104

335.7

135

506.5

 

 

 

 

 

 

 

 

43

125.0

74

214.0

105

340.5

136

512.9

 

 

 

 

 

 

 

 

44

127.3

75

217.4

106

345.3

137

519.3

 

 

 

 

 

 

 

 

45

129.7

76

220.9

107

350.1

138

525.8

 

 

 

 

 

 

 

 

46

132.2

77

224.4

108

355.0

139

532.4

 

 

 

 

 

 

 

 

47

134.6

78

228.0

109

360.0

140

539.0

 

 

 

 

 

 

 

 

48

137.1

79

231.6

110

365.0

141

545.6

 

 

 

 

 

 

 

 

49

139.6

80

235.3

111

370.0

142

552.3

 

 

 

 

 

 

 

 

50

142.2

81

239.0

112

375.1

143

559.1

 

 

 

 

 

 

 

 

51

144.8

82

242.7

113

380.2

144

565.9

 

 

 

 

 

 

 

 

52

147.4

83

246.5

114

385.4

145

572.8

 

 

 

 

 

 

 

 

53

150.1

84

250.3

115

390.7

146

579.8

 

 

 

 

 

 

 

 

54

152.8

85

254.1

116

396.0

147

586.8

 

 

 

 

 

 

 

 

55

155.5

86

258.0

117

401.3

148

593.8

 

 

 

 

 

 

 

 

56

158.2

87

262.0

118

406.7

149

601.0

 

 

 

 

 

 

 

 

57

161.0

88

266.0

119

412.2

150

608.1

 

 

 

 

 

 

 

 

58

163.9

89

270.0

120

417.7

151

615.4

 

 

 

 

 

 

 

 

59

166.7

90

274.1

121

423.2

152

622.7

 

 

 

 

 

 

 

 

60

169.6

91

278.2

122

428.8

153

630.1

 

 

 

 

 

 

 

 

61

172.6

92

282.3

123

434.5

154

637.5

 

 

 

 

 

 

 

 

62

175.4

93

286.5

124

440.2

155

645.0

 

 

 

 

 

 

 

 

Page 29

XP16 SERIES

Page 29
Image 29
Lenox Elite Series XP16 Units Heat Pumps, P506640-01 installation instructions Normal Operating Pressures