Lexmark 248X, 249X manual Timing, Init

Models: 249X 248X

1 227
Download 227 pages 723 b
Page 95
Image 95

Pin

Line

Description

 

 

 

31

INIT*

INIT* from the system resets the printer to its initial power-

 

 

on-state. The BUSY line goes high, and any received data is

 

 

printed. When INIT* goes low, the printer resets to the power-

 

 

on default state. If data is in the USB buffer, the USB FIFO is

 

 

not reset.

 

 

 

32

ERROR*

The printer sets the ERROR* line low if the printer detects an

 

 

error or out-of-paper condition.

 

 

A critical error condition exists when both ERROR* and PE

 

 

are low.

 

 

 

33

GND

Ground level.

 

 

 

34-35

 

Not used.

 

 

 

36

SELECT IN

The printer does not respond to the DC1/DC3 code when this

 

 

signal, valid only in Epson mode, is low.

 

 

 

* Inverted logic (signal is active when low).

Timing

The following chart shows the timing in microseconds of these signals.

Section 6: Using the Printer Interface

95

 

Page 95
Image 95
Lexmark 248X, 249X manual Timing, Init