Lexmark 249X, 248X manual Mode and Horizontal Density 249x Only, Mode Dec, Horizontal Density Wires

Models: 249X 248X

1 227
Download 227 pages 723 b
Page 50
Image 50

Bit Number

Binary Value

Print Wires

 

 

 

2

4

14, 15

 

 

 

1

2

16, 17

 

 

If dots 1 and 0 print, wire 18 is also used.

 

 

 

0

1

19, 20

 

 

 

Mode and Horizontal Density (249x Only)

For 249x printers only.

Use this command to select the mode and horizontal density for dot matrix graphics.

Format

ESC

[

g

Ln

Hn

mode

data

Decimal

27

91

103

Ln

Hn

mode

data

Hex

1B

5B

67

Ln

Hn

mode

data

Usage Notes

Ln and Hn identify the number of bytes in mode and data. To print less than 256 bytes:

Hn is 0.

Ln is the number of bytes you want to print, plus 1 for the mode byte. To print more than 256 bytes:

Divide the number of bytes you want to print (plus 1 mode byte) by 256.

The result is Hn.

The remainder is Ln.

mode is the vertical wire count and the horizontal density in dots per inch. Select mode from the following table.

 

Mode

 

 

 

 

 

 

 

Dec

 

Hex

Horizontal Density

Wires

 

 

 

 

 

0

 

00

60

8

 

 

 

 

 

1

 

01

120

8

 

 

 

 

 

2

 

02

120

8

 

 

 

 

 

3

 

03

240

8

 

 

 

 

 

50

Section 3: IBM Emulation Mode Printer Commands