Lexmark 248X Using an IBM AT Personal Computer RS-232C, Serial Communication Parameters RS-232C

Models: 249X 248X

1 227
Download 227 pages 723 b
Page 99
Image 99

Using an IBM AT Personal Computer (RS-232C)

If you are using an IBM AT or compatible computer, use a 9-pin to 25-pin EIA RS-232C cable.

We recommend one of the following for a 9-pin to 25-pin cable:

IBM P/N 6450242 (254 mm or 10 in.)

IBM P/N 6450217 (3 m or 10 ft.)

The following illustration shows the pin assignments for the 9-pin to 25-pin RS-232C serial cable.

IBM 9-Pin to 25-Pin Adapters 6450242 (254 mm or 10 in.) 6450217 (30.4 m or 10 ft.)

Lexmark Null Modem Serial Cable 1038693 (15.24 m or 50 ft.)

 

 

Shield

 

DCD

1

1

 

RXD

2

2

TXD

TXD

3

3

RXD

DTR

4

4

RTS

GND

5

5

CTS

DSR

6

6

DSR

RTS

7

7

GND

CTS

8

8

DCD

 

 

20

DTR

RI

9

22

 

 

9 (F)

25 (M)

 

Shield

 

F. GND

 

1

 

2

2

TXD

3

3

RXD

4

4

RTS

5

5

CTS

6

6

DSR

7

7

L. GND

8

20

DTR

20

25 (F)

25 (M)

 

Serial Communication Parameters (RS-232C)

The acceptable values for serial communications parameters follow.

Voltage Level Range

The maximum voltage level range for control lines or data lines is from

± 25 positive V dc to ± 25 negative V dc.

Section 6: Using the Printer Interface

99

 

Page 99
Image 99
Lexmark 248X, 249X Using an IBM AT Personal Computer RS-232C, Serial Communication Parameters RS-232C, Voltage Level Range