Series 610 UPS
Models:
1000kVA
1
1
120
120
Download
120 pages
52.8 Kb
1
2
3
4
5
6
7
8
Specs
Error messages
Customer Alarm Interface
Inverter Fault
Maintenance
System Configuration Screens
Reporting a Problem
Manual Reset
Series 610 terminal commands
Timeout
Page 1
Image 1
AC P
OWER
S
YSTEMS
S
ERIES
610™ UPS
O
PERATION
& M
AINTENANCE
M
ANUAL
100-1000kVA,
60Hz Three Phase
Multi-Module
Page 1
Page 2
Page 1
Image 1
Page 1
Page 2
Contents
Series 610 UPS
Battery Cabinet Precautions
Table of Contents
Specifications
Maintenance
Figures
Tables
Important Safety Instructions
Multi-Module UPS, 100-500kVA
System Description
Multi-Module UPS, 500-750kVA
Types of System Control Cabinets SCCs
Reliability
Designed for Success
Input Power Failure
Safety Precautions
Modes of Operation
Other Factors to Consider
Operator Controls
1989-2003
Options
Battery
Module Battery Disconnect
Battery Racks or Cabinets
Three Breaker Maintenance Bypass
Two Breaker Maintenance Bypass
System Control Cabinet
General Component Descriptions
UPS Module
Battery Plant
Controls Hardware
Detailed Component Descriptions
Software
Rectifier/Charger
Input Power Factor
Operation
Input Circuit Breaker
Battery Disconnect
Battery Charging Circuit
Battery Charge Current Limiting
Battery Equalize Charge Circuit
Unbalanced Load Characteristics
Non-Linear Load Characteristics
Inverter
Output Regulation and Overload Performance
Fuse Protection
Static Bypass
Shorted SCR Monitoring
Pulsed Parallel Operation
Static Switch Isolation
Load Transfers
Transfer and Retransfer Conditions
Retransfer Inhibited
Redundant Mode
Display Screen and Operator Controls
Features
1000kVA
500kVA
Description Function
Operation
Numbers are used as keys to data in , below
Refer to 3.4.5 Shutdown Procedures
Description Location Function
Switches behind SCC control panel door
Menu tree
Menu Tree Navigation
SCC Master Menu
Master Menu Screen
Module Master Menu
Operation
Input Metering Displays
SCC Monitor/Mimic Display Screen
Output Metering Displays
Item 7 Alarm Messages
Status/Alarm Message Areas
Item 5 Module Status Messages
Item 6 System Status Messages
Module Monitor/Mimic display screen
Module Monitor/Mimic Display Screen
Item 5 Alarm Messages
Alarm Messages
Module Display
SCC Display
Monitor/Mimic display example Utility fail
KVA / 217 kW 325A 325A 325A
MOD On Line OFF Line SUM ALM
B-C C-A 0V 0V Not OK to Transfer Static Switch Connected
Walk-in display screen during start-up
Walk-In Display Screen
Present Status
Status Reports Screens
SCC Status Report
Event History
Module Status Report
History status report screens
History Status
Alarm in SCC Alarm in Module
Alarm conditions that freeze history data gathering
System Status
Battery Cycle Monitor-Module Only
Battery cycle monitoring summary screen
SCC system configuration screen
System Configuration Screens
Date screen
Date
Time screen
Time
Auto Dial
Auto dial setting screen
Maximum Auto-Retransfer Attempts
Modem Baud Rate
Language Selection
System Current Rating
System Options
Retransfer Attempts
Continuous Duty Static Switch Optional
Battery test screen-MMU only
SCC and module remote monitor indications
Remote Monitor
Module alarm limit settings screen
Alarm Limit Settings Screen
Temperature Limit Setting Optional
Battery Float Voltage
Refer to 3.4.3 Load Transfer Procedures for more details
Load Transfer Procedures Screen
Refer to 3.4.1 SCC Start-Up Procedure for more details
Start-Up Procedures Screen
Module start- up procedures screens
Shutdown Procedures Screen
SCC shutdown procedures screen
Battery time screen 15 minute discharge
Battery Time Screen Module Only
Elapsed Time Minutes
Upper Limit Actual Lower Limit
Operation
Meter calibration screen
Meter Calibration Screen
Battery equalize screen
Battery Equalize Screen
System Status Messages
Alarm and Status Messages Module Status Messages
Load Block Messages
Abbreviations used in alarm messages
Abbreviation Definition
Alarm messages meaning and corrective action
Static Switch
Manual Reset
Bypass Phase
Control Power
Inverter Fault
Reverse Power
Transfer
Module N Off
Overtemperature
Battery Overtemp
Timeout
New Alarm
Alarm Message
Alarm messages summary
Special Functions
Worldwide Reporting
Communication Interfaces
Auto-Dial
Requesting Information
Local Reporting to a Monitor
Local Reporting to a Terminal
Site Reporting SiteScan or Snmp
Remote Monitor Panel
Series 610 terminal commands
Separate / Simultaneous Outputs
Circuit breaker abbreviations Abbreviation Circuit Breaker
OK to Transfer
Load on Bypass
Load on bypass, UPS available
Momentary Overloads
Momentary overload, pulsed static bypass switch
Input power fail-load on battery
Input Power Failure-Load on Battery
One module off-line, load on UPS
One Module Off-Line
Load on UPS-battery not available
Off Battery
Emergency Modules Off
Refer to 3.4.5 Shutdown Procedures
Emergency power off
Remote Emergency Power Off
System Shutdown
Refer to 3.3.10 Maintenance Bypass
Load on maintenance bypass, two breakers
SCC Start-Up Procedure
Manual Procedures
Refer to 3.5 Automatic Operations for more details
Operation
Operation
SCC start-up procedures screen
UPS Module Start-Up
Module start-up procedures screen
Operation
Manual Transfer Instructions UPS Lead
Load Transfer Procedures
If the load is on Maintenance Bypass
Maintenance Bypass Load Transfers
If the load is on the UPS System Bypass
Shutdown Procedures System Shutdown Procedure
Module Shutdown Procedure
Automatic Operations
Remote Emergency Power Off Repo
Local Emergency Modules Off Lemo
Automatic Transfers to Bypass
Overloads Without Transfer
1000%
150%
Automatic Module Off-Line
Automatic Retransfers to UPS
Automatic Emergency Modules Off
Maintenance
Maintenance Agreements The Signature Program
Liebert Global Services
Professional Start-Up
Training
Record Log
Routine Maintenance
Air Filters
Limited Life Components
Battery Safety Precautions
Battery Maintenance
Avertissement
Number of Cells Battery Voltage VDC Nominal Float
Matching Battery Cabinets Optional
Battery voltage record
Battery retorque values
Rack-Mounted Batteries
Detection of Trouble
Torque specifications unless otherwise labeled
Torque Requirements
Upstream Feeder Circuit Breaker Setting Inspections
Reporting a Problem
Corrective Actions
Recommended Test Equipment
Rating
Power factor pf KVA
KVA
Environmental Conditions
Specifications applicable to environment
Battery Operation
Adjustments
Electrical Specifications
Specifications 112
Page
Company Behind the Products
Technical Support/Service
Locations
United States
Top
Page
Image
Contents