| TROUBLESHOOTING | |||
|
|
|
|
|
| Observe all Safety Guidelines detailed throughout this manual | |||
|
|
|
|
|
| PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED | |
| (SYMPTOMS) | MISADJUSTMENTS(S) | COURSE OF ACTION |
|
|
|
|
|
|
PROBLEMS
F. Engine will not start.
1. | Spark plug boot or wire off, loose or | 1. | Dry and Place boot firmly onto spark |
| wet. |
| plug. |
2. | Low oil and engine protection system | 2. | Check and fill oil to proper level. |
| will not allow engine to start. (Oil light |
|
|
| may flash when attemting to start |
|
|
| engine). |
|
|
3. | Fuel shutoff valve is closed. | 3. | Open valve by turning counterclock- |
|
|
| wise. |
4. | Choke left in lowest, downward posi- | 4. | Allow unit to set for several minutes. |
| tion and carburetor flooded. |
| Follow “Starting/ Shutdown |
|
|
| Instructions” section when starting |
|
|
| the engine. |
5. | Fuel line clogged or closed. | 5. | Check line and/or replace filter. DO |
|
|
| NOT RUN ENGINE WITHOUT AN |
|
|
| |
|
|
| alternate fuel tank or supply. |
6. | Recoil start will not engage with | 6. | Gently hit the blower housing and/or |
| engine. |
| pull the rope to its fully extended |
|
|
| position and rapidly wiggle. Repeat |
|
|
| until clutch engages with shaft and |
|
|
| resistance is felt. |
7. | Fouled spark plug. | 7. | Replace spark plug. Maintain proper |
|
|
| spark gap. |
8. | Engine requires service to head, | 8. | Take the machine to an authorized |
| head gasket, and/or valves. |
| Briggs & Stratton Service Dealer. |
9. | Float open in carburetor & gas leak- | 9. | Close fuel shutoff valve. Gently tap |
| ing from bowl. |
| on carburetor bowl until float seats. |
|
|
| If gas still leaks, repair carburetor per |
|
|
| B&S specifications. |
10. | Engine is siezed and recoil start will | 10. | Replace Engine. |
| not move. |
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
POWER ARC 5000