Lincoln Electric NA-5NF, NA-5SF service manual OUT of Voltage Range Shut Down Test

Models: NA-5S NA-5N NA-5SF NA-5NF

1 152
Download 152 pages 30.16 Kb
Page 106
Image 106

TOC

F-53

TROUBLESHOOTING & REPAIR

F-53

 

 

OUT OF VOLTAGE RANGE SHUT DOWN TEST (Continued)

Return to Section

to Section TOC

Return to Master

to Master TOC

TEST PROCEDURE

1.Remove input power to the NA-5

2.Using the 5/16" nutdriver open the control box PC board access door.

3.Locate the voltage PC board. Jumper together the "BYPASS" and “Common” pins on the NA-5 voltage PC board. See Figure F.6 (On older voltage boards these pins may be labeled "B"). This should disable the shut down circuit.

4.Connect to a Lincoln Electric CV power source per connection dia- gram. See the Installation section of this manual.

Return

Return to Section TOC

Return to Section TOC

Return

Return to Master TOC

Return to Master TOC

 

1/8 AMP FUSE

JUMPER

 

TOGETHER

 

BYPASS

COM

 

 

AUTO

 

 

NA-5

VOLTAGE G1556-[ ]

FIGURE F.6 VOLTAGE BOARD AND PIN LOCATIONS

NA-5

Page 106
Image 106
Lincoln Electric NA-5NF, NA-5SF OUT of Voltage Range Shut Down Test, Figure F.6 Voltage Board and PIN Locations