Lincoln Electric NA-5NF, NA-5SF Circuit breaker trips when Power board may be faulty

Models: NA-5S NA-5N NA-5SF NA-5NF

1 152
Download 152 pages 30.16 Kb
Page 82
Image 82

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-29

TROUBLESHOOTING & REPAIR

F-29

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

 

RECOMMENDED

 

(SYMPTOMS)

 

MISADJUSTMENTS(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

 

 

 

 

 

The circuit breaker trips when the

1.

The power board may be faulty.

1.

Perform the Wire Drive Motor

inch up, inch down, or start buttons

 

Replace.

 

Test.

 

are pressed.

 

 

 

 

 

 

 

 

 

2. Perform the DC Power Supply

 

 

 

 

 

Test.

 

 

 

 

 

 

The circuit breaker trips and or the

1.

Contact your Local Lincoln

1.

If fuse F101 or the circuit breaker-

fuse (F101) blows when the NA-5 is

 

Authorized Field Service Facility.

 

immediately fails when input

turned on. (input power applied).

 

 

 

power is applied,

unplug all of

 

 

 

 

 

the PC boards except the power

 

 

 

 

 

board. If the fuse still fails the

 

 

 

 

 

power board may be faulty. If

 

 

 

 

 

the fuse does not fail reconnect

 

 

 

 

 

the PC boards one at a time until

 

 

 

 

 

the faulty board is located. Also

 

 

 

 

 

check and inspect the wiring har-

 

 

 

 

 

ness for “short” or “grounds”.

 

 

 

 

 

Reconnect the PC boards in the

 

 

 

 

 

following order: control,

 

 

 

 

 

voltage,logic,procedure,option-

 

 

 

 

 

timer, remote interface,speedme-

 

 

 

 

 

ter and voltmeter.

 

 

 

 

 

 

NOTE: Some of the above PC

 

 

 

 

 

boards are optional and may not

 

 

 

 

 

be used in all NA-5 control units.

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

NA-5

Page 82
Image 82
Lincoln Electric NA-5NF, NA-5SF service manual Circuit breaker trips when Power board may be faulty