Lincoln Electric NA-5NF, NA-5SF service manual Perform the DC Power Supply, Transformer Test

Models: NA-5S NA-5N NA-5SF NA-5NF

1 152
Download 152 pages 30.16 Kb
Page 65
Image 65

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-12

TROUBLESHOOTING & REPAIR

F-12

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

 

POSSIBLE AREAS OF

 

RECOMMENDED

 

 

(SYMPTOMS)

 

 

MISADJUSTMENTS(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

MODE FUNCTION PROBLEMS

 

 

 

 

 

 

 

 

The speed and voltage controls do

 

1.

Check lights 1A and 1B located

1.

If lights 1A and /or 1B are OFF

not function. All of the mode lights

 

 

on the power board. They should

 

perform the DC Power Supply

function properly.

 

 

both be ON.

 

Test.

 

 

 

 

2.

If both lights 1A and 1B are ON

2.

Perform the T1 and T2

 

 

 

 

 

the control board may be faulty.

 

Transformer Test.

 

 

 

 

 

Replace.

 

 

 

 

 

 

 

 

3. The power board may be faulty.

 

 

 

 

 

 

Replace.

 

 

 

 

 

 

 

 

All the mode lights function properly.

 

1.

The control board may be faulty.

 

 

 

None of the speed controls operate

 

 

Replace.

 

 

 

properly.

 

 

 

 

 

 

 

All the mode lights function properly.

 

1.

The voltage board may be faulty.

 

 

 

None of the voltage controls operate

 

 

Replace.

 

 

 

properly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

NA-5

Page 65
Image 65
Lincoln Electric NA-5NF, NA-5SF service manual Perform the DC Power Supply, Transformer Test