F-18

TROUBLESHOOTING & REPAIR

F-18

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

 

 

POSSIBLE AREAS OF

 

RECOMMENDED

 

 

(SYMPTOMS)

 

 

 

MISADJUSTMENTS(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

MODE FUNCTION PROBLEMS

 

 

 

 

 

 

 

 

 

 

The burnback timer does not time

 

1.

Test if the other timers (start,

1.

Check the lead harness between

 

out properly.

 

 

 

weld, crater) function properly. If

 

the burnback module and the pro-

 

 

 

 

 

they time out correctly the burn-

 

cedure board for loose or faulty

 

 

 

 

 

back module may be faulty.

 

connections.

 

 

 

 

 

 

Replace.

 

 

 

 

 

 

 

2.

If the other timers (start, weld,

 

 

 

 

 

 

 

 

crater) do NOT function correctly

 

 

 

 

 

 

 

 

the procedure board may be

 

 

 

 

 

 

 

 

faulty.

 

 

 

 

 

 

 

 

 

 

 

 

The weld light does not light. The

 

1.

The procedure board may be

 

 

 

 

weld controls (voltage and wire feed

 

 

faulty. Replace.

 

 

 

 

speed) may or may not function.

 

 

 

 

 

 

 

The NA-5 is at idle with the selector

 

 

 

 

 

 

 

switch in the “Weld” position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The weld light is ON but the weld

 

1.

If the option boards (start and

 

 

 

 

controls (voltage and wire feed

 

 

crater) are not installed make

 

 

 

 

speed) do not function. The NA-5 is

 

 

sure the jumper plugs are

 

 

 

 

at idle with the selector switch in the

 

 

installed in the procedure board.

 

 

 

 

“Weld” postion.

 

 

 

 

 

 

 

 

 

 

 

2.

If the strike light is also lit (along

 

 

 

 

 

 

 

 

with the weld light) the logic

 

 

 

 

 

 

 

 

board may be faulty.

 

 

 

 

 

 

 

3.

The procedure board may be

 

 

 

 

 

 

 

 

faulty. Replace.

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

NA-5

Page 71
Image 71