Lincoln Electric SP-100 service manual Input Connections, Gas Solenoid Inlet Fitting, Power

Models: SP-100

1 62
Download 62 pages 13.43 Kb
Page 12
Image 12

A-5

INSTALLATION

Return to Section TOC

Return to Section TOC

WARNING

BUILDUP OF SHIELDING GAS may harm health or kill.

• Shut off shielding gas supply when not in use.

SEE AMERICAN NATIONAL STANDARD Z-49.1, “SAFETY IN WELDING AND CUTTING” PUB- LISHED BY THE AMERICAN WELDING SOCIETY.

1.Chain the cylinder to a wall or other stationary sup- port to prevent the cylinder from falling over. Insulate the cylinder from the work circuit and earth ground.

FIGURE A.5

Flow Regulator

Cylinder Valve

3.Attach the flow regulator to the cylinder valve and tighten the union nut securely with a wrench. The flow regulator for carbon dioxide must have a plas- tic washer seated in the fitting that attaches to the cylinder to prevent leakage.

4.Refer to Figure A.6. Attach one end of inlet gas hose to the outlet fitting of the flow regulator and tighten the union nut securely with a wrench. Connect the other end to the SP-100 Gas Solenoid Inlet Fitting (5/8-18 female threads — for CGA — 032 fitting). Make certain the gas hose is not kinked or twisted.

INPUT CONNECTIONS

Refer to Figure A.6.

The SP-100 has two input connections, the power input cable, and the Gas Solenoid Inlet Fitting. Both connections are located on the rear of the machine.

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

FIGURE A.6

Gas Hose

Gas Solenoid

Inlet Fitting

2. With the cylinder securely installed, remove the

Power

cylinder cap. Stand to one side away from the out-

Input

let and open the cylinder valve very slightly for an

Cable

instant. This blows away any dust or dirt which may

 

have accumulated in the valve outlet.

 

WARNING

BE SURE TO KEEP YOUR FACE AWAY FROM THE VALVE OUTLET WHEN “CRACKING” THE VALVE. Never stand directly in front of or behind the flow regulator when opening the cylinder valve. Always stand to one side.

SP-100

Page 12
Image 12
Lincoln Electric SP-100 service manual Input Connections, Gas Solenoid Inlet Fitting, Power